Cisco temperature threshold
WebDec 8, 2024 · Operating temperature 1 23 to 113°F (–5 to 45°C) which indeed is a normal temperature >>> I read the temperature with SNMP and the values are around 70 ° C. <<< imaging you walk into an equipment room and the temperature in the room is 70 ° C !!! my guess is you are doing something wrong! 70 ° C is quite hot for operating temperature WebSep 23, 2024 · [no] event temperature [mod module-number] [sensor sensor-number] threshold {major minor any} In addition to the default policy, this example shows how to execute the policy myappletname and action 1 if the temperature crosses the minor threshold on sensor 3 of module 2: switch# configure terminal
Cisco temperature threshold
Did you know?
WebJul 17, 2024 · Looking at the above I see the temperature of the air flowing in is 27°c and the air flowing out is 30°c, which seem like reasonable values - but do they line up with the actual room temperature? The alarm values of 57°c on the incoming air and 125°c on the outgoing air seem a little high, but I guess it's all solid-state stuff and if they ... WebApr 4, 2024 · DiagThermalTest : This test verifies the temperature reading from the sensor is below the yellow temperature threshold. It is a non-disruptive test and can be run as a health monitoring test. DiagFanTest : This test verifies all fan modules have been inserted and working properly on the board It is a non-disruptive test and can be run as a ...
WebIf a command is not in the Cisco Catalyst 4500 Series Switch Command Reference , you can locate it in the Cisco IOS Master ... Temperature alarms are issued as soon as the temperature reaches the threshold temperature and are canceled when the temperature drops more than 5 degree C below the threshold. 5 degree C is a hysteresis value … WebJul 18, 2024 · temperature threshold configuration. 07-18-2024 10:33 AM. I have Catalyst 4500 L3 Switch, I want to configure temperature threshold and send the notifications to SNMP server, I tried the commands in the attached snapshot but the router not …
WebFeb 14, 2024 · Card temperature exceeds the critical threshold. Major . Red . 15 min . Syslog message displays when the alarm is issued. SeeTable 10-2 for the action on timeout. Card temperature exceeds the shutdown threshold. Major . Red . 30 sec . Syslog message displays when the alarm is issued. SeeTable 10-2 for the action on timeout. Supervisor … WebSep 9, 2013 · We use the ciscoEnvMonTemperatureStateTable (1.3.6.1.4.1.9.9.13.1.3.1.6). This returns 5 values (1-5) that indicate normal, warning, critical, shutdown or nonPresent. This way the device determines the alerted threshold values - and you can use the same alert rule for many device types (that all have different threshold values).
WebJun 24, 2024 · Learn more about how Cisco is using Inclusive Language. Book Contents Book Contents. Preface; Software Licensing; The Cisco IOS command-line interface (CLI) ... Sets the low temperature threshold value. Set the threshold from –328°F (–200°C) to 482°F (250°C). 4. end. Returns to privileged EXEC mode. 5. show alarm settings. north babylon dentalWebMar 13, 2013 · 2960 23 to 113°F (-5 to 45°C) 2950 32 to 113°F (0 to 45°C) 3750 32 to 113°F (0 to 45°C) 3560 32 to 113°F (0 to 45°C) Third -- What mibs can be monitored to actively check temperature? I am using: -- 1.3.6.1.4.1.9.5.1.2.13 -- chassisTempAlarm -- 1.3.6.1.4.1.9.9.13.1.3 -- ciscoEnvMonTemperatureStatusTable I have this problem too … north babylon fire co als trainingWebthreshold #1 for module 1 outlet temperature: (sensor value > 60) is system minor alarm threshold #2 for module 1 outlet temperature: (sensor value > 70) is system major alarm module 1 inlet temperature: 25C threshold #1 for module 1 inlet temperature: (sensor value > 60) is system minor alarm threshold #2 for module 1 inlet temperature: north babylon garbage collectionWeb2. alarm facility temperature primary high threshold Set the primary high temperature threshold value. 3. alarm facility temperature primary low threshold Set the primary low temperature threshold value. 4. exit Return to privileged EXEC mode. 5. show alarm settings Verify the configuration. how to replace drain stopper in sinkWebthreshold #1 for module 1 outlet temperature: (sensor value >= 75C) is system minor alarm threshold #2 for module 1 outlet temperature: (sensor value >= 90C) is system major alarm module 1 inlet temperature: 41C threshold #1 for module 1 inlet temperature: (sensor value >= 50C) is system minor alarm threshold #2 for module 1 inlet temperature: north babylon csdWebSwitch 3 - Temp Sensor 0, YELLOW : Inlet Temperature is above warning threshold: >46 Switch 1 - Temp Sensor 0, YELLOW : Inlet Temperature is above warning threshold: >46 Switch 3 - Temp Sensor 0, YELLOW : NON-INLET Temperature is above warning threshold: >105 north babylon floristWebMar 31, 2024 · TestThermal : This test verifies the temperature reading from the sensor is below the yellow temperature threshold. It is a non-disruptive test and can be run as a health monitoring test. TestScratchRegister : The Scratch Register test monitors the health of application-specific integrated circuits (ASICs) by writing values into registers and ... north babylon deli menu